Feeler Gauge Set 303-D027 (D81L-4201-A) or equivalent |
NOTE:
Refer to the appropriate Section 303-01 for the specification.
Use a Straightedge that is calibrated by the manufacturer to be flat within 0.005 mm (0.0002 in) per running foot of length, such as Snap-On® GA438A or equivalent. For example, if the Straightedge is 61 cm (24 in) long, the machined edge must be flat within 0.010 mm (0.0004 in) from end to end.
Use a Straightedge and a Feeler Gauge Set to inspect the cylinder block for flatness.
Ford Focus Battery Tray
Removal and Installation
Remove the battery. For additional information, refer to Battery in this
section.
Remove the 3 nuts from the battery tray.
To install, tighten to 12 Nm (106 lb-in).
Remove the 4 wire harness pushpins from the battery tray and remove the
t ...