Feeler Gauge Set 303-D027 (D81L-4201-A) or equivalent |
NOTE:
Refer to the appropriate Section 303-01 for the specification.
Use a Straightedge that is calibrated by the manufacturer to be flat within 0.005 mm (0.0002 in) per running foot of length, such as Snap-On® GA438A or equivalent. For example, if the Straightedge is 61 cm (24 in) long, the machined edge must be flat within 0.010 mm (0.0004 in) from end to end.
Use a Straightedge and a Feeler Gauge Set to inspect the cylinder block for flatness.
Ford Focus Climate Control System - General Information and Diagnostics
Climate Control System Operation
WARNING: Take the following
precautions when repairing an air conditioning system containing R-134a:
Always wear safety goggles.
Avoid contact with liquid refrigerant R-134a. R-134a vaporizes at approximately
-25°C (-13°F) under atmospheric pressure ...