Ford Focus Service Manual: Air Cleaner Outlet Pipe
- Disconnect the crankcase ventilation tube and vacuum tube from the Air Cleaner
(ACL) outlet pipe.
- Loosen the 2 ACL outlet pipe clamps.
- Remove the ACL outlet pipe.
- To install, tighten to 3 Nm (27 lb-in).
- To install, reverse the removal procedure.
Intake Manifold (View 1 of 3)
Item
Part Number
Description
1
14A464
Engine Oil Pressure (EOP) switch electrical connector (part of 12C508)
2
...
Item
Part Number
Description
1
—
Air inlet mode door actuator electrical connector (part of 18B604)
2
—
Air inlet duct screw (2 require ...
More about Ford Focus:
Ford Focus Refrigerant Identification Testing
Special Tool(s)
Refrigerant Blend Identifier with Printer
198-00012 or equivalent
Refrigerant Identification
NOTE: A Refrigerant Blend Identifier with Printer must be used
to identify gas samples taken directly from the refrigeration system or storage